Double Tapped Neutrals: This Isn’t A New Rule

While I try to make most of my blog posts somewhat generic and appealing to most, this one ain't that.  This post is about a very specific electrical defect that I frequently run across, and I'm writing this post so I can give my clients a better explanantion of this defect.  Oh, and also so I can give my clients proof that this isn't some new requirement that I just heard about.

Double Tapped Neutral The problem I'm addressing today is double tapped neutral lugs in electric panels.  A 'double tapped neutral' is another way of saying that one of the screws on the neutral bus bar in the panelboard has more than one neutral wire feeding to it.  This is a no-no, and has been for very long time.

One reason that two neutral wires can't be connected to a single terminal in a panelboard is so that the circuit can be isolated if it needs to be worked on.  There is a great explanation of this at the Schneider-Electric web site.  The other reason you can't have two neutral wires connected under a single lug is because the connections might come loose.  While panel manufacturers will allow for up to three grounding conductors under a single lug, they typically only allow one neutral wire.  The grounding conductors aren't going to normally carry current for extended periods of time, so they have a very slim possibility of coming loose.  This isn't the case with the neutral conductors. 

Despite what many seem to think, this didn't become a new requirement in 2002.  This has been a requirement of UL 67 for a long time, but was spelled out in the NEC in 2002.   Oh, and for the record, if a home inspector recommends a repair of say, a double tapped neutral, they're doing it for the reasons listed above; not because it's "code".

Reuben Saltzman, Structure Tech Home Inspections - EmailHome Inspections in Minnesota

Facebook Reuben's LinkedIn Page Follow StructureTech on Twitter ASHI Certified Home Inspector - Click To Verify Click to subscibe to Reuben's Blog

Written By

Reuben is a second-generation home inspector with a passion for his work. He grew up remodeling homes and learning about carpentry since he was old enough to hold a hammer. Reuben grew up thinking he was going to be a school teacher because he enjoyed teaching others so much. In a sense, that’s a lot of what home inspections are about, so Reuben truly does what he loves. Sharlene has worked with Structure Tech since 2000 and Reuben has been contributing to her blog since 2008.

Subscribe to Our Newsletter for Market Updates & Mid-Century Modern Listings

Our weekly HomesMSP Update includes current local market information and a curated list of mid-century modern properties for sale, plus posts from an inspector, a lender, a stager, info about neighborhoods, life in the Twin Cities… even recipes!

Hidden

Blog Categories

Archives

Sharon and John Hensrud

About Us

The HomesMSP Team is committed to meeting you where you are and listening… really listening to understand you so we can use our extensive knowledge of the market and local neighborhoods to give you personalized service.