Water heater warranties: mind the fine print. They’re not all the same!

I’ve had a point-of-use water heater leak on me twice now, and it was less than three years old both times. I shared those stories in a couple of blog posts: My kitchen disaster, and Kitchen disaster… averted!

I’m somewhat familiar with water heater warranties; I’ve helped many friends replace failed water heaters, many times within the warranty period, and it has never been a hassle. We’ve simply brought the water heater back to the original place of purchase, and the retailer has provided a replacement. Easy peasy. But not anymore.

No more Mr. Nice Guy

After my most recent water heater failure, I brought my 2.5-gallon, 2.5-year-old Bosch water heater back to the place of purchase with my receipt in hand, expecting to have the warranty honored there. I was quite surprised when they told me “no can do”. They’ve changed their return and warranty policies and insisted I would have to take this up with the manufacturer directly. So that’s what I did.

I contacted Bosch, and they just needed a few simple things from me to send out a new water heater. They needed proof of purchase: check. Proof of the leak: heck yes, I took a great video showing the leaking tank. And finally, a photo of the magnesium anode rod. Insert record scratch sound here.

Wait, what? You want a photo of the anode rod? Okay, sure, I can do that… but I don’t like where this is going.

So I took the water heater apart, and here’s what I found:

Anode rod missing

Do you see the problem? There’s NO ANODE ROD! In just 2.5 years, it has completely disintegrated away to nothing. Oof. That says a lot about the properties of my Maple Grove water. Here’s what a brand-new anode rod for a tiny water heater looks like:

New anode rod

No anode rod = no warranty

I sent the photo of my missing anode rod to Bosch, and their response was no surprise. Under the warranty fine print of items not covered, #8 says “Damage caused by lack of maintenance of anode rod.” And in the user manual, they have some stern warnings about maintaining the anode rod. Check it out:

It is critical that the anode rod be inspected once a year to detemine whether it requires replacement (and it must be replaced at least once every two years).

Wow. To inspect this anode rod, I need to uninstall the water heater completely, drain it, and take it apart. At that point, I don’t really care what the anode rod looks like. If I’m going through this much work, I will simply replace it right there and then. After all, new anode rods only cost about $10 apiece. So from now on, I intend to replace my water heater anode rod at least every year. I’ve already ordered a few replacement anode rods, and I’ll update this blog post every year with photos of my old anode rods to document the process.

Conclusion

Do all manufacturers have a super-restrictive warranty like this? No. When it comes to other brands, they’re not nearly as picky as Bosch about their anode rods. I checked the warranties for point-of-use water heaters from Rheem, Ariston, Eemax, and Ecosmart. Some say you “should” check the anode rod annually, but they don’t use words like “critical” and “must”. And most importantly, there’s no warranty exclusion related to the anode rod from any of them.

In short, the next time I purchase a point-of-use water heater, I won’t make the fatal assumption that all of the warranties are the same. But I already replaced this one, so I’ll be doing some serious annual maintenance on it until it leaks again.

Written By

Reuben is a second-generation home inspector with a passion for his work. He grew up remodeling homes and learning about carpentry since he was old enough to hold a hammer. Reuben grew up thinking he was going to be a school teacher because he enjoyed teaching others so much. In a sense, that’s a lot of what home inspections are about, so Reuben truly does what he loves. Sharlene has worked with Structure Tech since 2000 and Reuben has been contributing to her blog since 2008.

Related Posts

Anode rod gone

Water Heater Anode Rod: Gone in One Year!

🖨 Print Article I installed a new 2.5-gallon point-of-use water heater under my kitchen sink exactly one year ago. My old one failed after less than three years, and it...

Subscribe to Our Newsletter for Market Updates & Mid-Century Modern Listings

Our weekly HomesMSP Update includes current local market information and a curated list of mid-century modern properties for sale, plus posts from an inspector, a lender, a stager, info about neighborhoods, life in the Twin Cities… even recipes!

This field is hidden when viewing the form

Blog Categories

Archives

Sharon and John Hensrud

About Us

The HomesMSP Team is committed to meeting you where you are and listening… really listening to understand you so we can use our extensive knowledge of the market and local neighborhoods to give you personalized service.