Bedroom ceiling height and floor area requirements for 1.5-story homes

Ceiling height and floor area requirements for bedrooms in 1.5-story homes seem to befuddle everyone. I teach a lot of CE classes to real estate agents, and whenever I get to the part about ceiling height, there are a bunch of questions regarding these homes. To start, let’s go over the requirements for all rooms, then we’ll discuss the tricky ones.

Here’s a video discussion: https://youtu.be/7KhkWaxOP48

Ceiling Height Requirements

For new buildings, the minimum allowable ceiling height is 7′. According to section R305 of the Minnesota State Building Code, this applies to habitable space, hallways, bathrooms, toilet rooms, laundry rooms, and portions of basements containing these spaces.

For existing buildings, the minimum allowable ceiling height for finished basement areas, including bedrooms, is 6′ – 4″. This includes beams, ducts, girders, and other obstructions, and this height must be maintained all the way to the exterior door. For anything outside of the basement, the ceiling height must still be 7′. Click the link above for all of the little details.

Floor area requirements

Habitable rooms, other than kitchens, must have a floor area of not less than 70 square feet. In addition to this, rooms need to measure at least 7′ in every horizontal direction. This is found under section R304 of the Minnesota State Building Code.

Tricky rooms: bedrooms in 1.5-story homes

The building code says that for rooms with sloped ceilings, at least half of the required floor area must have a ceiling height of at least 7′. You can count the sloped ceiling area down to 5′, but nothing after that. To make it really simple, you need at least 3-1/2′ of ceiling that’s at least 7′ high. Here’s a crude drawing that’s probably not to scale, courtesy of me. The numbers in the drawing are all minimum dimensions.

Ceiling height requirements

So what does this have to do with home inspections? Not much, really. But as a licensed Truth-In-Sale of Housing (TISH) Evaluator, I’m supposed to verify this stuff when doing TISH evaluations.

Author: Reuben SaltzmanStructure Tech Home Inspections

Subscribe button

Written By

Reuben is a second-generation home inspector with a passion for his work. He grew up remodeling homes and learning about carpentry since he was old enough to hold a hammer. Reuben grew up thinking he was going to be a school teacher because he enjoyed teaching others so much. In a sense, that’s a lot of what home inspections are about, so Reuben truly does what he loves. Sharlene has worked with Structure Tech since 2000 and Reuben has been contributing to her blog since 2008.

Subscribe to Our Newsletter for Market Updates & Mid-Century Modern Listings

Our weekly HomesMSP Update includes current local market information and a curated list of mid-century modern properties for sale, plus posts from an inspector, a lender, a stager, info about neighborhoods, life in the Twin Cities… even recipes!

Hidden

Blog Categories

Archives

Sharon and John Hensrud

About Us

The HomesMSP Team is committed to meeting you where you are and listening… really listening to understand you so we can use our extensive knowledge of the market and local neighborhoods to give you personalized service.