Five Common Home Inspection Issues with Sump Systems

At almost every home inspection with a sump system, I end up recommending some type of change for safety, performance, or both. Here are five common sump system defects, in no particular order.

1. A loose or missing sump basket cover

Loose sump basket coverThis is a safety issue because a small child could drown if they fell in to a sump basket.  The fix for this condition is quite simple; if there’s no cover, install one.  If the cover is loose, get a few 3″ drywall screws and run the screws right through the cover in to the sides of the sump basket.  A good rule of thumb is to also make sure the sump cover can support someone’s weight, for obvious reasons.

Ideally, the sump cover should also be airtight.  This will help to preventradon gases from entering the home, as well as moist air.

2. A missing check valve

A check valve should be installed on the discharge pipe to prevent water in the discharge tubing from dumping back in to the sump basket after the pump shuts off.

Check valve diagram

This is also a simple fix; check valves cost about $10 and are easy to install.

3. An undersized discharge pipe

Improper discharge tubeSump pumps typically have a 1-1/4″ or 1-1/2″ outlet.  The size of the discharge tubing should match this; that means don’t use a garden hose.  Using undersized discharge tubing, even at the exterior, will force the pump to run longer each time it turns on, decreasing the life of the pump.  Some smaller pumps may come with an adapter for a garden hose, but those are the exception.

The fix for this condition is simple; use larger tubing.  Inside the house, use ABS or PVC tubing. Outside the house it’s not nearly as important.  Home improvement stores sell 25′ lengths of corrugated tubing for under $10, and connecting these is a piece of cake.

Corrugated discharge tube

4. Discharging water right against the house

When a sump pump discharges water right up against the house at the exterior, where does the water go?  Right back down in to the sump system!  While this might seem to be extremely obvious, experience has told me that it might not be, because this is a very common defect.  The discharge tube from the sump system should terminate at a point where the water will drain away from the building.

5. A potential for freezing at the exterior

I’m embarrassed to say that I actually had this happen to me last year. I typically remove my discharge hose at the exterior in the fall, but I forgot to do it last year.  Water ended up freezing inside the tubing, completely blocking it.  One morning I noticed a low humming noise that never stopped, and I found my sump pump running continuously, unable to pump the water out.  I can only imagine how long the pump had been running before I found out about it, and how many years of service this stupid mistake might have removed from my pump.

Sump disharge to flex hose

While disconnecting the drain hose at the exterior will prevent the sump discharge from being blocked by ice, there’s another way to prevent blockage that doesn’t require any maintenance.  Simply have the sump pump discharge to an air gap. This way, if the discharge tubing fills with ice at the exterior, water will still make it’s way out. It will end up discharging right up against the house if the tubing is frozen, but it’s better than not discharging at all, and the amount of water that a sump pump pumps during the winter should be minimal.

The photo below shows the sump pump discharging to a receptor that connects to a 4″ corrugated drain hose.

Sump pump discharge with air gap

Just be sure to significantly increase the size of the drain hose if going with this method; if the drain hose isn’t large enough, water will overflow very quickly.

Next week I’ll discuss discharging a sump pump into the sanitary sewer.

Quick Links: Missing cover  |  Missing check valve  |  Undersized discharge  |  Short discharge  |  Potential for freezing

Author: Reuben Saltzman, Structure Tech Home Inspections

          

Written By

Reuben is a second-generation home inspector with a passion for his work. He grew up remodeling homes and learning about carpentry since he was old enough to hold a hammer. Reuben grew up thinking he was going to be a school teacher because he enjoyed teaching others so much. In a sense, that’s a lot of what home inspections are about, so Reuben truly does what he loves. Sharlene has worked with Structure Tech since 2000 and Reuben has been contributing to her blog since 2008.

Related Posts

How to test a sump pump

🖨 Print Article Failed sump pumps lead to flooded basements. While it’s important to have a backup plan in place for a failed sump pump, it’s also a good idea to...

Five things to look for in a sump pump

🖨 Print Article This is a guest blog post by Steve Grohn, CEO of Standard Water Control Systems.  Considering a new sump pump or backup system? Here’s what you need...

Subscribe to Our Newsletter for Market Updates & Mid-Century Modern Listings

Our weekly HomesMSP Update includes current local market information and a curated list of mid-century modern properties for sale, plus posts from an inspector, a lender, a stager, info about neighborhoods, life in the Twin Cities… even recipes!

Hidden

Blog Categories

Archives

Sharon and John Hensrud

About Us

The HomesMSP Team is committed to meeting you where you are and listening… really listening to understand you so we can use our extensive knowledge of the market and local neighborhoods to give you personalized service.